Standard Panel Inserts

Contact us for more information.

Standard Panel Inserts

Application: Panel insert for thermocouple and RTD circuits.

Construction:

  • Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
  • Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
  • Stainless combo head screws (slot and phillips)

Color code:

  • ANSI color code stocked. Available in all color code standards (JIS, BS, NFE, etc.). Call for availability. See color code at bottom of page.
  • Temperature rating: 392 F (200 C)
  • Wire size: Accepts wire sizes for 40 to 20 gauge (Max)

Flanged Bracket Mounting

Application: Panel insert for thermocouple and RTD circuits.Mounting by means of a stainless steel bracket and screws.

Construction:

  • Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
  • Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
  • Stainless combo head screws. (slot and phillips)

Color code:

  • ANSI color code stocked. Available in all color code standards (JIS, BS, NFE, etc.). Call for availability. See color code at bottom of page.
  • Temperature rating: 392 F (200 C)
  • Wire size: Accepts wire sizes for 40 to 20 gauge (Max)

Round Direct Mount

Application: Panel insert for thermocouple and RTD circuits. Mounting by means of two screws on the front.

Construction:

  • Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
  • Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
  • Stainless combo head screws. (slot and phillips)

Color code:

  • ANSI color code stocked. Available in all color code standards (JIS, BS, NFE, etc.). Call for availability. See color code at bottom of page.
  • Temperature rating: 392 F (200 C)
  • Wire size: Accepts wire sizes for 40 to 20 gauge (Max)

Round Bracket Mount

Application: Panel insert for thermocouple and RTD circuits Suited for small wires. Mounting by means of two screws with a bracket behind the panel.

Construction:

  • Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
  • Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
  • Stainless combo head screws. (slot and phillips)

Color code:

  • ANSI color code stocked. Available in all color code standards (JIS, BS, NFE, etc.). Call for availability. See color code at bottom of page.
  • Temperature rating: 392 F (200 C)
  • Wire size: Accepts wire sizes for 40 to 20 gauge (Max)

Lugged Panel Insert

Application: Panel insert for thermocouple and RTD circuits. Can be mounted in a single circuti version or in rows in customer panels. Mounting by means of two M3 screws.

Construction:

  • Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
  • Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
  • Stainless combo head screws. (slot and phillips)

Color code:

  • ANSI color code stocked. Available in all color code standards (JIS, BS, NFE, etc.). Call for availability. See color code at bottom of page.
  • Temperature rating: 392 F (200 C)
  • Wire size: Accepts wire sizes for 40 to 20 gauge (Max)

Three Pin Lugged

Application: Panel insert for thermocouple and RTD circuits. Third connection for ground or continuous shield or for three wire RTD's. Can be mounted in a single circuit version or in rows in customer panel. Mounting by means of two M3 screws.

Construction:

  • Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
  • Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
  • Stainless combo head screws. (slot and phillips)

Color code:

  • ANSI color code stocked. Available in all color code standards (JIS, BS, NFE, etc.). Call for availability. See color code at bottom of page.
  • Temperature rating: 392 F (200 C)
  • Wire size: Accepts wire sizes for 40 to 20 gauge (Max)

High Temperature

Application: Panel insert for thermocouple and RTD circuits.

Construction:

  • Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
  • Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
  • Stainless combo head screws. (slot and phillips)

Color code:

  • ANSI color code stocked. Color brown. Calibration indicated by colored dot
  • Temperature rating: 662 F (350C)
  • Wire size: Accepts wire sizes for 40 to 20 gauge (Max)

Three Pin High Temperature

Application: Panel insert for thermocouple and RTD circuits.

Construction:

  • Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
  • Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
  • Stainless combo head screws. (slot and phillips)

Color code:

  • ANSI color code stocked. Body color black. Calibration indicated by colored dot.
  • Temperature rating: 662 F (350 C)
  • Wire size: Accepts wire sizes for 40 to 20 gauge (Max)