Standard Panel Inserts
Contact us for more information.
Standard Panel Inserts
Application: Panel insert for thermocouple and RTD circuits.
Construction:
- Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
- Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
- Stainless combo head screws (slot and phillips)
Color code:
- ANSI color code stocked. Available in all color code standards (JIS, BS, NFE, etc.). Call for availability. See color code at bottom of page.
- Temperature rating: 392 F (200 C)
- Wire size: Accepts wire sizes for 40 to 20 gauge (Max)
Flanged Bracket Mounting
Application: Panel insert for thermocouple and RTD circuits.Mounting by means of a stainless steel bracket and screws.
Construction:
- Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
- Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
- Stainless combo head screws. (slot and phillips)
Color code:
- ANSI color code stocked. Available in all color code standards (JIS, BS, NFE, etc.). Call for availability. See color code at bottom of page.
- Temperature rating: 392 F (200 C)
- Wire size: Accepts wire sizes for 40 to 20 gauge (Max)
Round Direct Mount
Application: Panel insert for thermocouple and RTD circuits. Mounting by means of two screws on the front.
Construction:
- Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
- Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
- Stainless combo head screws. (slot and phillips)
Color code:
- ANSI color code stocked. Available in all color code standards (JIS, BS, NFE, etc.). Call for availability. See color code at bottom of page.
- Temperature rating: 392 F (200 C)
- Wire size: Accepts wire sizes for 40 to 20 gauge (Max)
Round Bracket Mount
Application: Panel insert for thermocouple and RTD circuits Suited for small wires. Mounting by means of two screws with a bracket behind the panel.
Construction:
- Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
- Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
- Stainless combo head screws. (slot and phillips)
Color code:
- ANSI color code stocked. Available in all color code standards (JIS, BS, NFE, etc.). Call for availability. See color code at bottom of page.
- Temperature rating: 392 F (200 C)
- Wire size: Accepts wire sizes for 40 to 20 gauge (Max)
Lugged Panel Insert
Application: Panel insert for thermocouple and RTD circuits. Can be mounted in a single circuti version or in rows in customer panels. Mounting by means of two M3 screws.
Construction:
- Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
- Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
- Stainless combo head screws. (slot and phillips)
Color code:
- ANSI color code stocked. Available in all color code standards (JIS, BS, NFE, etc.). Call for availability. See color code at bottom of page.
- Temperature rating: 392 F (200 C)
- Wire size: Accepts wire sizes for 40 to 20 gauge (Max)
Three Pin Lugged
Application: Panel insert for thermocouple and RTD circuits. Third connection for ground or continuous shield or for three wire RTD's. Can be mounted in a single circuit version or in rows in customer panel. Mounting by means of two M3 screws.
Construction:
- Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
- Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
- Stainless combo head screws. (slot and phillips)
Color code:
- ANSI color code stocked. Available in all color code standards (JIS, BS, NFE, etc.). Call for availability. See color code at bottom of page.
- Temperature rating: 392 F (200 C)
- Wire size: Accepts wire sizes for 40 to 20 gauge (Max)
High Temperature
Application: Panel insert for thermocouple and RTD circuits.
Construction:
- Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
- Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
- Stainless combo head screws. (slot and phillips)
Color code:
- ANSI color code stocked. Color brown. Calibration indicated by colored dot
- Temperature rating: 662 F (350C)
- Wire size: Accepts wire sizes for 40 to 20 gauge (Max)
Three Pin High Temperature
Application: Panel insert for thermocouple and RTD circuits.
Construction:
- Glass filled thermoplastic body with polarized pins made from thermocouple material with male and spring loaded female inserts.
- Wire connection under cap- sandwich style (for secure connection) with barrier (helps prevent shorts)
- Stainless combo head screws. (slot and phillips)
Color code:
- ANSI color code stocked. Body color black. Calibration indicated by colored dot.
- Temperature rating: 662 F (350 C)
- Wire size: Accepts wire sizes for 40 to 20 gauge (Max)